RTP1200 rapid heating tube furnace

  • DSC_2094.jpg
  • DSC_2108.jpg
  • DSC_2112.jpg
  • DSC_2118.jpg
  • Technical Parameters
  • Detailed Description
  • Video show
  • The standard configuration
  • Option

model

RTP1200

power

12KW

Furnace tube

Quartz tube: 100 * 600mm (pipe diameter is optional)

Put a furnace plug on each side. The furnace plug can block the heat radiation in the center of the furnace tube. It must be placed in the correct position of the furnace before heating.

Overall dimensions (LXWXH)

1000X500X750mm

voltage

380V

Phase

Simplex

Heating element

12 iodine tungsten lamps

Temperature control method

Eurotherm

The use of imported instruments makes the temperature response faster and the temperature control more sensitive.

3504 temperature meter

1: High-precision temperature meter, LCD liquid crystal display, 5-digit numerical display, simple configuration through quick setting, and C / F unit switching.

2: 50 groups of programs with 500 steps, power off or shutdown, restart the program can be set to start the program from the power off or the starting point, and also has the functions of running, pause, skip, stop, reset, etc.

3: Standard 3 groups of PID parameters (optional 8 groups of PID parameters), with built-in PID self-tuning function.

4: Math / logic operation, timer function, alarm function, do math and logic operation function, such as automatic / manual switching of sensor and infrared sensor, high temperature furnace logic control function, and related alarm strategies and functions.

5: Recipe function, different products can call different parameters

6: Customer-defined screen function, displaying current value, set value, output%, program running status and time, etc.

7: Support various communication interfaces Modbus, Ethernet, Profibus, Devicenet, can be integrated with any PLC or higher-level system

8: OEM password function

9: Multilingual support (English, French, German, Spain, Italy)

10: PC version of iTools graphical configuration software, easy to configure, monitor and debug

11: UL / CE certification

Continental Instruments    

Furnace material

1. High-quality high-purity alumina polycrystalline fiber curing furnace formed by vacuum suction filtration.

2. Molded by Japanese technology.

3.The spacing and pitch of the resistance wires in the furnace are all arranged according to the best thermal technology in Japan, and the temperature field is simulated by thermal software

control precision

+/- 1 ℃

trigger

Phase shift trigger

Electrical appliances

Zhengtai

Thyristor

106 / 16E Simmonk, Germany

Maximum temperature

≤1000 ℃

Heating section length

240mm

Heating rate

≤50 ℃ / S (can be modified according to requirements)

Thermocouple model

K type

Ambient surface temperature

≤45 ℃

Cover opening protection system

When the furnace cover is opened, the relay will automatically cut off the main power, effectively ensuring the safety of the user.

Vacuum system

(Optional)

1.Single- stage pump TW-1.5A 2.Double-stage pump 2XZ-2 3.VS -0.1 vacuum system

4. VS high vacuum system 5. Constant pressure pump 6. British PCG550 (INFICON) capacitance vacuum gauge

1. Generally use a rough vacuum to drive the gas out of the furnace tube: TW-1.5A single-stage pump can be used.

2. The two-stage pump 2XZ-2 vacuum pump can draw the vacuum degree of the tube furnace tube to about 10Pa.

3. The VS-0.1 vacuum system can draw the vacuum degree in the tube furnace tube to 0.1Pa (with a resistance vacuum gauge display).

4, VS high vacuum system (this system is composed of molecular and mechanical pump) can draw the vacuum degree in the tube furnace tube to 10-3 Pa.

5. Constant pressure pump (This system can control the pressure in the tube at -100.0KPa ~ 100.0KPa).

6. British (INFICON) capacitance vacuum gauge (measurement range 3.8x10-5 -1125 Torr, can detect various gases, including mixed gases, accurate measurement, good repeatability, optional anti-corrosion type PCG554)

Flange and valve

Gas supply system

(Optional)

1. Bubbler 2. Mass flow meter gas supply system 3. Liquid evaporator

warranty period

One year warranty, lifetime technical support

Special tips: 1. Consumable parts such as heating elements, quartz tubes, sample crucibles, etc. are not under warranty.

2. Damage caused by the use of corrosive gases and acid gases is not covered by the warranty.

Precautions

1. The air pressure in the furnace tube cannot be higher than 0.02MPa

2. Due to the high internal pressure of the gas cylinder, when introducing gas into the furnace tube, a pressure reducing valve must be installed on the gas cylinder. In order to ensure safety, it is recommended to use a pressure lower than 0.02 MPa.

3. When the furnace temperature is higher than 1000 ° C, the furnace tube must not be in a vacuum state. The pressure in the furnace tube must be equal to the atmospheric pressure.

4. The gas flow entering the furnace tube needs to be less than 200SCCM to avoid the impact of the cold air flow on the hot furnace tube

5. For the experiment of sample heating, it is not recommended to close the suction valve and inlet valve of the flange end of the furnace tube. If you need to close the gas valve to heat the sample, you must always pay attention to the indication of the pressure gauge. If the pressure is greater than 0.02MPa, you must immediately open the exhaust valve to prevent accidents (such as furnace tube rupture, flange flying out, etc.)

The furnace is open type, the furnace body adopts a double-layer shell structure, and the furnace is made of alumina polycrystalline fiber material imported from Japan. Since the maximum heating rate can reach 50 ° C / s, the substrate film can be quickly returned. There is a travel switch that automatically cuts off the power when the furnace lid is opened.

1. Installed with air switch and leakage protector:

When the circuit is over-current or leakage, the meeting will be disconnected automatically.

2.Can connect with computer

The furnace is equipped with a communication interface and software, which can directly control various parameters of the furnace through a computer, and can observe the PV and SV temperature values on the furnace and the operation of the instrument from the computer. The actual heating curve of the furnace will be drawn by the computer in real time And can save the temperature data at each moment, you can call up at any time

3. Furnace

                   

1. High-quality high-purity alumina polycrystalline fiber curing furnace formed by vacuum suction filtration.

2. Molded by Japanese technology.

3.The spacing and pitch of the resistance wires in the furnace are all arranged according to the best thermal technology in Japan, and the temperature field is simulated by thermal software.

4. Adopting 4 weeks heating, the temperature field is more balanced

4. Optional UL certified electrical board (all imported electrical appliances that passed UL certification)

5, certification

6, feet

Description

Quantity

image

RTP1200 tube furnace

1 set

Quartz tube

1

Stainless steel flange

1 set

Stainless steel stove hook

1

Hearth plug

1 pair

High temperature gloves

1 pay

COM to USB interface (optional)

1 set

Manual

1 serving

Software (optional)

1 serving



online service
  • After sales service After sales service
  • Product consultation Product consultation
  • Product consultation Product consultation
support hotline
  • 4008-051-061
Only focus can be professional
Sales Hotline: 4008-051-061
025-83111681
025-83693678
13913006686
15190487889
After sales phone: 15850763891
Technical support: 13611581149
Company Fax: 025-83111571
"Sweep code and pay attention to discounts"
捕鱼大作战---首页_欢迎您 JJ干瞪眼,欢乐干瞪眼,天天干瞪眼,干瞪眼玩法规则 JJ干瞪眼-首页 ope体育 传统足彩_竞彩网