This tube furnace is equipped with a nickel-based alloy holder, which can be placed on the holder for sintering. The size of the holder can be customized. Please confirm with the sales when order

Type

TL1200-1200-1200-I

TL1200-1200-1200-II

TL1200-1200-1200-III

Work rate

15KW

18KW

24KW

Furnace tube

Quartz tube: 150/200/250 * 1800mm (pipe diameter is optional)

Put a furnace plug on each side. The furnace plug can block the heat radiation in the center of the furnace tube. It must be placed in the correct position of the furnace before heating.

Dimensions

1900X600X800

1900X650X850

1900X700X900

voltage

380V

Phase

Three phase

Heating element

Sweden Kanthal A1 imported resistance wire (resistance wire can be guaranteed for 2 years) Click to enter the information

Temperature control method

Use Yudian program temperature control instrument (standard)

1. 30-segment program temperature control intelligent PID adjustment.

2. With over-temperature protection, the electric furnace heating circuit will be automatically cut off when the temperature is too high or the temperature is broken. ON, the ON light on the panel is off, the OFF light is on, and the electric furnace is limitedly protected).

3. With 485 communication interface (standard with optional software)

4. It has a power failure protection function, that is, when the furnace is powered on after the power is turned off, the program does not start from the initial temperature, but starts from the furnace temperature when the power is turned off.

5.The meter has the function of temperature self-tuning

(Replacement of imported instruments requires additional payment, purchase)

FP93 temperature control instrument (Japan Shiden) Eurometer instrument touch screen instrument

Furnace material

1. High-quality high-purity alumina polycrystalline fiber curing furnace formed by vacuum suction filtration.

2. Molded by Japanese technology.

3.The spacing and pitch of the resistance wires in the furnace are all arranged according to the best thermal technology in Japan, and the temperature field is simulated by thermal software.

Domestic Furnace Imported Furnace

Valves and flanges

control precision

+/- 1 ℃

trigger

Phase shift trigger

Electrical appliances

Zhengtai

Thyristor

106 / 16E Simmonk, Germany

Maximum temperature in the first, second and third temperature zones

1200 ℃

Rated temperature in the first, second and third temperature zones

1100 ℃

Heating rate

≤30 ℃ / Min (can be modified according to requirements)

Recommended heating rate

≤15 ℃ / Min

Thermocouple model

K type

Heating section length

400mm + 400 + 400mm

Length of the constant temperature section in the first, second and third temperature zones

900-1000mm

Temperature field curve

Ambient surface temperature

≤45 ℃

Cover opening protection system

When the furnace cover is opened, the relay will automatically cut off the main power, effectively ensuring the safety of the user.

Vacuum system

(Optional)

1.Single- stage pump TW-1.5A 2.Double-stage pump 2XZ-2 3.VS -0.1 vacuum system

4. VS high vacuum system 5. Constant pressure pump 6. British PCG550 (INFICON) capacitance vacuum gauge

1. Generally use a rough vacuum to drive the gas out of the furnace tube: TW-1.5A single-stage pump can be used.

2. The two-stage pump 2XZ-2 vacuum pump can draw the vacuum degree of the tube furnace tube to about 10Pa.

3. The VS-0.1 vacuum system can draw the vacuum degree in the tube furnace tube to 0.1Pa (with a resistance vacuum gauge display).

4, VS high vacuum system (this system is composed of molecular and mechanical pump) can draw the vacuum degree in the tube furnace tube to 10-3 Pa.

5. Constant pressure pump (This system can control the pressure in the tube at -100.0KPa ~ 100.0KPa).

6. British (INFICON) capacitance vacuum gauge (measurement range 3.8x10-5 -1125 Torr, can detect various gases, including mixed gas, accurate measurement, good repeatability, optional anticorrosion type PCG554)

7. You can choose a cold vacuum trap in our company to avoid pollution to the vacuum pump,

Cold trap

Gas supply system

(Optional)

1. Bubbler 2. Mass flow meter gas supply system 3. Liquid evaporator

Tube furnace installation instructions (click to enter)

Cylinder pressure reducing valve specifications selection precautions, tube furnace installation instructions (click to enter)

warranty period

One year warranty, lifetime technical support

Special tips: 1. Consumable parts such as heating elements, quartz tubes, sample crucibles, etc. are not under warranty

2. Damage caused by the use of corrosive gases and acid gases is not covered by the warranty.

Precautions

1. The air pressure in the furnace tube cannot be higher than 0.02MPa

2. Due to the high internal pressure of the gas cylinder, when introducing gas into the furnace tube, a pressure reducing valve must be installed on the gas cylinder. In order to ensure safety, it is recommended to use a pressure lower than 0.02 MPa.

3. When the furnace temperature is higher than 1000 ° C, the furnace tube must not be in a vacuum state. The pressure in the furnace tube must be equal to the atmospheric pressure.

4. The gas flow entering the furnace tube needs to be less than 200SCCM to avoid the impact of the cold air flow on the hot furnace tube

5. For the experiment of sample heating, it is not recommended to close the suction valve and inlet valve of the flange end of the furnace tube. If you need to close the gas valve to heat the sample, you must always pay attention to the indication of the pressure gauge. If the pressure is greater than 0.02MPa, you must immediately open the exhaust valve to prevent accidents (such as furnace tube rupture, flange flying out, etc.)

1.Swedish Kanthal A1 resistance wire

Kanthal A1 raw silk domestic resistance wire hearth VS imported resistance wire hearth

(1), the surface temperature can reach 1420

(2) The surface is stainless steel (very bright, pay attention when customers identify it), will not rust, and will not drop slag even if it is used for a long time.

(3), Kanthal resistance wire data download

(4) Kanthal resistance wire website: www.kanthal.com

(5), resistance balance, temperature field balance is good

                                                                                        

Fe-Cr-Al Alloy doped by Mo resistance wire produced by Shougang used by most manufacturers Kanthal A1 resistance wire has uniform resistance and balanced heat generation

Sometimes the resistance is not balanced, part of the heat is large, part of the heat is small, and the temperature field works well

2. Installed air switch and leakage protector:

When the circuit is over-current or leakage, the meeting will be disconnected automatically.

3.Can connect with computer

The furnace is equipped with a communication interface and software, which can directly control various parameters of the furnace through a computer, and can observe the PV and SV temperature values on the furnace and the operation of the instrument from the computer. The actual heating curve of the furnace will be drawn by the computer in real time And can save the temperature data at each moment, you can call up at any time

Furnace

1. High-quality high-purity alumina polycrystalline fiber curing furnace formed by vacuum suction filtration.

2. Molded by Japanese technology.

3.The spacing and pitch of the resistance wires in the furnace are all arranged according to the best thermal technology in Japan, and the temperature field is simulated by thermal software.

4. Adopting 4 weeks heating, the temperature field is more balanced

5. Optional UL certified electrical board (all imported electrical appliances that passed UL certification)

6, certification

7, feet

8.Alumina furnace plug

9.Stainless steel support frame

 

 

Description

Quantity

image

TL1200 tube furnace

1 set

Quartz tube

1

Stainless steel flange

1 set

Stainless steel stove hook

1

K-type thermocouple

3 pieces

Hearth plug

1 pair

High temperature gloves

1 pay

COM to USB interface (optional)

1 set

Manual

1 serving

Software (optional)

1 serving

Gas supply system

Proton flow meter gas supply system

Float meter air supply system

Extraction system

Vacuum pump

2XZ-2

TW-1.5A

FX-16

Pfeiffer Molecular Pumps

Resistance vacuum gauge

Resistance vacuum gauge

Composite vacuum gauge

Bellows

KF25

KF40

Vacuum baffle valve

KF25

KF40

KF card holder

KF25

KF40

KF Tee

KF25



online service
  • After sales service After sales service
  • Product consultation Product consultation
  • Product consultation Product consultation
support hotline
  • 4008-051-061
Only focus can be professional
Sales Hotline: 4008-051-061
025-83111681
025-83693678
13913006686
15190487889
After sales phone: 15850763891
Technical support: 13611581149
Company Fax: 025-83111571
"Sweep code and pay attention to discounts"
捕鱼大作战---首页_欢迎您 JJ干瞪眼,欢乐干瞪眼,天天干瞪眼,干瞪眼玩法规则 JJ干瞪眼-首页 ope体育 传统足彩_竞彩网